Highlights | Specifications | To Order | |
Products | Home |
Need to comply with ISO-9000 reporting specifications? These meters can help. All conform to the temperature/voltage tables of the National Institute of Standards and Technology (N.I.S.T.). OMEGA provides a free NIST Traceable Certificate of Calibration for your records.
Since ISO-9000 requires that calibration be done at the equipment site, these meters are a perfect choice. With 0.5° accuracy in an ambient temperature range of 64° to 82°F, you╒re not confined to the lab. Take it everywhere. The ABS plastic case protects it from dust, dirt. |
The OMEGA CL20 series calibrator/
thermometers simulate, measure and record RTD, ohm, thermocouple and thermistor signals╨all in one meter. They outperform the competition
in the lab and on the factory floor with 0.5°F accuracy and in ambient temperatures from 18° to 28°C
( 64° to 82° F).
This powerful handheld meter allows the user to calibrate in the field as well as in the lab and offers many additional functions that translate into cost-effectiveness, increased productivity and long-lasting versatility and reliability.
The 5-digit LCD display indicates all active functions and allows users to have 0.1° resolution in both Fahrenheit and Celsius. This convenient display takes the guesswork out of which sensor has been selected, displaying °F or °C and operating mode.
Programming a CL20 series calibrator is a snap. The keypad allows direct entry of calibrator setpoints. Setpoints can also be entered from an outside source by inputting temperatures or voltages through the thermometer mode. There are no reprogramming hassles. The program won╒t be lost when the meter is shut off. All values are retained and can be retrieved for fast repeat use.
These calibrators feature 10 memory locations that can instantly recall any programmed value, and the step function lets the user run through the test points at the push of a button. This efficient feature saves time by allowing the user to just enter the output value and calibrate.
The ramp function of Models CL25 and CL27 makes calibrating switch and alarm setpoints quick and easy. By entering the upper limit, lower limit and step size, the meter automatically ramps between the limits. There is also a manual ramp function.
No matter what thermocouple type is used, one of these meters can handle it. Features to choose from include 100 ohm and 1000 ohm RTD and 2252 ohm thermistor capabilities.
CL20 Series Temperature Measurement and Calibration Range
|
CL26 and CL27 Resistance Measurement and Calibration Outputs
CL20 Series Accessories
|
To Order (Specify Model Number) | ||||||||
Model Number | Price | TC Types | Platinum RTDs | Thermistor | Resistance 0 to: | Resistance Resolution | Accuracy Calibrator & Thermometer | Ramp Feature |
CL23A* | 545 | K,J,T | -- | -- | -- | -- | ±0.5°F from -50 to 1250°F 0.04% over 1250°F ±1.0°F under -50°F | -- |
CL23EC* | 545 | K,T, E, J-DIN | -- | -- | -- | -- | ±0.5°F from -50 to 1250°F 0.04% over 1250°F ±1.0°F under -50°F | -- |
CL24 | 600 | K,J,T,E | -- | -- | -- | -- | ±0.5°F from -50 to 1250°F 0.04% over 1250°F ±1.0°F under -50°F | -- |
CL25 | 845 | K,J,T,E,N,R, | -- | -- | -- | -- | ±0.5°F full scale K,J,T,E,N 1.5°F full scale B,R,S,G,C,D | Yes |
CL25EC | 845 | K,J,T,E,N,R, S,B,G,C,J-DIN | -- | -- | -- | -- | ±0.5°F full scale K,J,T,E,N,1.5°F full scale B,R,S,G,C,D,J-DIN | Yes |
CL26 | 895 | K,J,T,E | 100 ohm | 400 Series 2252 ohm | 100k ohm 100 ohm | 1 ohm 0.01 ohm | ±0.5°F from -50 to 1250°F 0.04% over 1250°F ±1.0°F under -50°F Ohms: 0.04% of range ±0.5°F RTD & thermistor | -- |
CL27 | 1095 | K,J,T,E,N,R, S,B,G,C,D | 100 ohm 1000 ohm | -- | 1k ohm 100 ohm | 0.1 ohm 0.01 ohm | ±0.5°F full scale K,J,T,E,N ±1.5°F full scale B,R,S,G,C,D Ohms: 0.02% of range 0.2°F full scale RTD | Yes |
CL27EC | 1095 | K,J,T,E,N,R, S,B,G,C,J-DIN | 100 ohm 1k ohm | -- | 1000 ohm 100 ohm | 0.1 ohm 0.01 ohm | ±0.5°F full scale K,J,T,E,N ±1.5°F full scale B,R,S,G,C,D, J-DIN; Ohms: 0.02% of range 0.2°F full scale RTD | Yes |
CL28MA | 495 | 0 to 21 mA simulator/meter | ±0.05% of range | Yes | ||||
*Note: Not compatible with Type E thermocouple Each CL20 series unit is supplied as a complete kit with 4 beaded wire thermocouples (J,K,T,E), 4 TAS standard to mini thermocouple adaptors (J,K,T,E), 4 calibration cables (J,K,T,E), shock resistant holster, belt clip, integral tilt stand/handle, wrist strap, rugged carrying case, and certificate of calibration. The CL26 and CL27 also include one 3-wire RTD calibration cable, one 2-wire resistance cable and one TA4F RTD adaptor. CL23A does not include type E thermocouple, adaptor or cable. Ordering Examples: CL24 J/K/T/E calibration/thermometer kit, $600. CL26 J/K/T/E, thermistor and RTD calibration/thermometer kit, $895. |
|
|